You must enable Javascript on your browser for the site to work optimally and display sections completely.

Companies found: 7
Abb Spa (11719)
Siemens Spa (6470)
Eaton Industries (Italy) S.r.l. (1957)
Schneider Electric Spa (1221)
Bticino Spa (1037)
Hager Bocchiotti SPA (431)
Gewiss Spa (264)

Power circuit-breaker for trafo/generator/installation protection

Results 1-12 of 23099
Code
Details
NZMH2-VE100-S1 INT MAGN 3P 100A 1000V SELET - 100777 (4015081006779)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 100 A
Rated voltage: 1000÷1000 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA
Overload release current setting: 50÷100 A
Adjustment range short-term delayed short-circuit release: 100÷1000 A
Eaton Industries (Italy) S.r.l.
Details
NZMH2-VE160-S1 INT MAGN 3P 160A 1000V SELET - 100778 (4015081006786)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 160 A
Rated voltage: 1000÷1000 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA
Overload release current setting: 80÷160 A
Adjustment range short-term delayed short-circuit release: 160÷1600 A
Eaton Industries (Italy) S.r.l.
Details
NZMH2-VE250-S1 INT MAGN 3P 250A 1000V SELET - 100779 (4015081006793)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 250 A
Rated voltage: 1000÷1000 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA
Overload release current setting: 125÷250 A
Adjustment range short-term delayed short-circuit release: 250÷2500 A
Eaton Industries (Italy) S.r.l.
Details
NS1-63-NA INT SEZ 35KA 480V 63A UL/CSA - 102681 (4015081025411)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 63 A
Rated voltage: 690÷690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA
Overload release current setting: 0÷0 A
Adjustment range short-term delayed short-circuit release: 0÷0 A
Eaton Industries (Italy) S.r.l.
Details
NS1-100-NA INT SEZ 35KA 480V 100A UL/CSA - 102682 (4015081025428)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 100 A
Rated voltage: 690÷690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA
Overload release current setting: 0÷0 A
Adjustment range short-term delayed short-circuit release: 0÷0 A
Eaton Industries (Italy) S.r.l.
Details
NS1-125-NA INT SEZ 35KA 480V 125A UL/CSA - 102683 (4015081025435)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 125 A
Rated voltage: 690÷690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA
Overload release current setting: 0÷0 A
Adjustment range short-term delayed short-circuit release: 0÷0 A
Eaton Industries (Italy) S.r.l.
Details
NS2-160-NA INT SEZ 160A UL/CSA 100KA - 102684 (4015081025442)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 160 A
Rated voltage: 690÷690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA
Overload release current setting: 0÷0 A
Adjustment range short-term delayed short-circuit release: 0÷0 A
Eaton Industries (Italy) S.r.l.
Details
NS2-200-NA SEZIONATORE 200A UL/CSA - 102685 (4015081025459)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 200 A
Rated voltage: 690÷690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA
Overload release current setting: 0÷0 A
Adjustment range short-term delayed short-circuit release: 0÷0 A
Eaton Industries (Italy) S.r.l.
Details
NS2-250-NA SEZIONATORE 250A UL/CSA - 102686 (4015081025466)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 250 A
Rated voltage: 690÷690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA
Overload release current setting: 0÷0 A
Adjustment range short-term delayed short-circuit release: 0÷0 A
Eaton Industries (Italy) S.r.l.
Details
NS3-400-NA SEZ 100KA 480V 400A UL/CSA - 102687 (4015081025473)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 400 A
Rated voltage: 690÷690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA
Overload release current setting: 0÷0 A
Adjustment range short-term delayed short-circuit release: 0÷0 A
Eaton Industries (Italy) S.r.l.
Details
NS3-600-NA SEZ 100KA 480V 600A UL/CSA - 102688 (4015081025480)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 600 A
Rated voltage: 690÷690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA
Overload release current setting: 0÷0 A
Adjustment range short-term delayed short-circuit release: 0÷0 A
Eaton Industries (Italy) S.r.l.
Details
NS4-800-NA SEZ 65KA 480V 800A UL/CSA - 102689 (4015081025497)
power circuit-breaker for trafo/generator/installation protection
Rated permanent current Iu: 800 A
Rated voltage: 690÷690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Overload release current setting: 0÷0 A
Adjustment range short-term delayed short-circuit release: 0÷0 A