Power circuit-breaker for trafo/generator/installation protection
Code | ||
---|---|---|
NZMN2-4-A300/200 INT.AUT.4P 300A 50KA N 60% - 107587 (4015081072675) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 300 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 240÷300 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH2-4-A300 INT.AUT.4P 300A 50KA N 100% - 107588 (4015081072682) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 300 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA Overload release current setting: 240÷300 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH2-4-A300/200 INT.AUT.4P 300A 50KA N 60% - 107589 (4015081072699) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 300 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA Overload release current setting: 240÷300 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB2-AF60-BT-NA INT. MAGN. 3P(UL/CSA) - 107619 (4015081072859) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 60 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 60÷60 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB2-AF100-BT-NA INT. MAGN. 3P(UL/CSA) - 107623 (4015081072897) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 100 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 100÷100 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB2-AF175-BT-NA INT. MAGN. 3P(UL/CSA) - 107627 (4015081072934) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 175 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 175÷175 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB2-AF250-BT-NA INT. MAGN. 3P(UL/CSA) - 107630 (4015081072965) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 250 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 250÷250 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH2-A32-BT-NA INT. MAGN. 3P(UL/CSA) - 107799 (4015081074464) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 32 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA Overload release current setting: 25÷32 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH2-A50-BT-NA INT. MAGN. 3P(UL/CSA) - 107801 (4015081074488) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 50 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA Overload release current setting: 40÷50 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH2-A63-BT-NA INT. MAGN. 3P(UL/CSA) - 107802 (4015081074495) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 63 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA Overload release current setting: 50÷63 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH2-A80-BT-NA INT. MAGN. 3P(UL/CSA) - 107803 (4015081074501) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 80 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA Overload release current setting: 63÷80 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMC3-A320 INT.AUT.DI POT.3P PROT. IMPIANTI - 109665 (4015081092512) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 320 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 36 kA Overload release current setting: 250÷320 A Adjustment range short-term delayed short-circuit release: 0÷0 A |