Companies found: 12
Abb Spa (416) |
Siemens Spa (261) |
Eaton Industries (Italy) S.r.l. (197) |
Lovato Electric Spa (109) |
Pizzato Elettrica Srl (37) |
Bticino Spa (27) |
Omron Electronics S.p.a. (22) |
Gewiss Spa (17) |
Hager Bocchiotti SPA (16) |
Palazzoli Spa (14) |
Italweber Spa (5) |
Bremas Ersce Spa (2) |
Code | ||
---|---|---|
CONTATTO 1 N.A.10A 250V - GW74201 (8011564065611) auxiliary contact block Number of contacts as change-over contact: - Number of contacts as normally open contact: 1 Number of contacts as normally closed contact: - Number of fault-signal switches: - Rated operation current Ie at AC-15, 230 V: 3 A | ||
CONTATTO 1 N.C.10A 250V - GW74202 (8011564065628) auxiliary contact block Number of contacts as change-over contact: - Number of contacts as normally open contact: - Number of contacts as normally closed contact: 1 Number of fault-signal switches: - Rated operation current Ie at AC-15, 230 V: 3 A | ||
CONTATTO 1 N.A.10A 250V - GW74501 (8011564822986) auxiliary contact block Number of contacts as change-over contact: - Number of contacts as normally open contact: 1 Number of contacts as normally closed contact: - Number of fault-signal switches: - Rated operation current Ie at AC-15, 230 V: 3 A | ||
CONTATTO 1 N.C.10A 250V - GW74502 (8011564822993) auxiliary contact block Number of contacts as change-over contact: - Number of contacts as normally open contact: - Number of contacts as normally closed contact: 1 Number of fault-signal switches: - Rated operation current Ie at AC-15, 230 V: 3 A | ||
CONTATTO 2 N.O. 10A 250V - GW74503 (8011564823051) auxiliary contact block Number of contacts as change-over contact: - Number of contacts as normally open contact: 2 Number of contacts as normally closed contact: - Number of fault-signal switches: - Rated operation current Ie at AC-15, 230 V: 3 A | ||
CONTATTO 2 N.C. 10A 250V - GW74505 (8011564823075) auxiliary contact block Number of contacts as change-over contact: - Number of contacts as normally open contact: - Number of contacts as normally closed contact: 2 Number of fault-signal switches: - Rated operation current Ie at AC-15, 230 V: 3 A | ||
CONTATTO AUX ATS 100A 160A - GW97774 (8011564764668) auxiliary contact block Number of contacts as change-over contact: 3 Number of contacts as normally open contact: - Number of contacts as normally closed contact: - Number of fault-signal switches: - Rated operation current Ie at AC-15, 230 V: 5 A | ||
CONTATTI AUX.MSS 160 - GW98514 (8011564211698) auxiliary contact block Number of contacts as change-over contact: 1 Number of contacts as normally open contact: - Number of contacts as normally closed contact: - Number of fault-signal switches: - Rated operation current Ie at AC-15, 230 V: 5 A | ||
CONTATTI AUX.MSS 250-630 - GW98515 (8011564211704) auxiliary contact block Number of contacts as change-over contact: 1 Number of contacts as normally open contact: - Number of contacts as normally closed contact: - Number of fault-signal switches: - Rated operation current Ie at AC-15, 230 V: 16 A | ||
CONTATTI AUX.COMMUTAT. - GW98516 (8011564211711) auxiliary contact block Number of contacts as change-over contact: 1 Number of contacts as normally open contact: - Number of contacts as normally closed contact: - Number of fault-signal switches: - Rated operation current Ie at AC-15, 230 V: 5 A | ||
pulsante- Blocco 1cont.deviaz. term saldare - A161-16007600000 (4536853010263) auxiliary contact block Number of contacts as change-over contact: 1 Number of contacts as normally open contact: 0 Number of contacts as normally closed contact: 0 Rated operation current Ie at AC-15, 230 V: 3 A Type of electric connection: Soldering flag connection | ||
pulsante- Blocco 2cont.deviaz. term.saldare - A162-16007700000 (4536853010270) auxiliary contact block Number of contacts as change-over contact: 2 Number of contacts as normally open contact: 0 Number of contacts as normally closed contact: 0 Rated operation current Ie at AC-15, 230 V: 3 A Type of electric connection: Soldering flag connection |