You must enable Javascript on your browser for the site to work optimally and display sections completely.

Companies found: 13
Siemens Spa (522)
Abb Spa (416)
Schneider Electric Spa (376)
Eaton Industries (Italy) S.r.l. (197)
Lovato Electric Spa (109)
Pizzato Elettrica Srl (37)
Bremas Ersce Spa (35)
Bticino Spa (27)
Omron Electronics S.p.a. (23)
Gewiss Spa (17)
Hager Bocchiotti SPA (16)
Palazzoli Spa (14)
Italweber Spa (9)

Auxiliary contact block

Results 85-96 of 1798
Code
Details
CONTATTI AUX 2NA PER SEZ. 20-160A - HZC312 (3250613140786)
bloc de contact auxiliaire
Number of contacts as change-over contact: 0
Number of contacts as normally open contact: 0
Number of contacts as normally closed contact: 2
Number of fault-signal switches: -
Rated operation current Ie at AC-15, 230 V: 6
Hager Bocchiotti SPA
Details
CONTATTI AUX 1NA+1NC PER COMM. MOT. - HZI300 (3250613362928)
bloc de contact auxiliaire
Number of contacts as change-over contact: 3
Number of contacts as normally open contact: 0
Number of contacts as normally closed contact: 0
Number of fault-signal switches: -
Rated operation current Ie at AC-15, 230 V: 5
Hager Bocchiotti SPA
Details
Contatto di segnalazione aggiuntivo - M8AGG (8012199969749)
bloc de contact auxiliaire
Number of contacts as change-over contact: 1
Number of contacts as normally open contact: 0
Number of contacts as normally closed contact: 0
Number of fault-signal switches: -
Rated operation current Ie at AC-15, 230 V: 16
Bticino Spa
Details
Contatto pronto a chiudere molle cariche - M8PC (8012199969701)
bloc de contact auxiliaire
Number of contacts as change-over contact: 0
Number of contacts as normally open contact: 1
Number of contacts as normally closed contact: 1
Number of fault-signal switches: -
Rated operation current Ie at AC-15, 230 V: 16
Bticino Spa
Details
megabreak - contatti per ausiliari - M8SB (8012199972190)
bloc de contact auxiliaire
Number of contacts as change-over contact: 1
Number of contacts as normally open contact: 0
Number of contacts as normally closed contact: 0
Number of fault-signal switches: -
Rated operation current Ie at AC-15, 230 V: 16
Bticino Spa
Details
CONTATTO AUX 1NC - 8LM2TC01 (8013975036624)
bloc de contact auxiliaire
Number of contacts as change-over contact: 0
Number of contacts as normally open contact: 0
Number of contacts as normally closed contact: 1
Number of fault-signal switches: 0
Rated operation current Ie at AC-15, 230 V: 6
Lovato Electric Spa
Details
CONTATTO AUX 1NC RIT. - 8LM2TC01D (8013975036662)
bloc de contact auxiliaire
Number of contacts as change-over contact: 0
Number of contacts as normally open contact: 0
Number of contacts as normally closed contact: 1
Number of fault-signal switches: 0
Rated operation current Ie at AC-15, 230 V: 6
Lovato Electric Spa
Details
CONTATTO AUX 1NO - 8LM2TC10 (8013975036631)
bloc de contact auxiliaire
Number of contacts as change-over contact: 0
Number of contacts as normally open contact: 1
Number of contacts as normally closed contact: 0
Number of fault-signal switches: 0
Rated operation current Ie at AC-15, 230 V: 6
Lovato Electric Spa
Details
CONTATTO AUX 1NO ANT. - 8LM2TC10A (8013975036679)
bloc de contact auxiliaire
Number of contacts as change-over contact: 0
Number of contacts as normally open contact: 1
Number of contacts as normally closed contact: 0
Number of fault-signal switches: 0
Rated operation current Ie at AC-15, 230 V: 6
Lovato Electric Spa
Details
CONTATTO AUX 1NC ATT.VITE - LPXC01 (8013975189573)
bloc de contact auxiliaire
Number of contacts as change-over contact: 0
Number of contacts as normally open contact: 0
Number of contacts as normally closed contact: 1
Number of fault-signal switches: 0
Rated operation current Ie at AC-15, 230 V: 6
Lovato Electric Spa
Details
CONTATTO AUX 1NC RIT.ATT.VITE - LPXC01D (8013975189580)
bloc de contact auxiliaire
Number of contacts as change-over contact: 0
Number of contacts as normally open contact: 0
Number of contacts as normally closed contact: 1
Number of fault-signal switches: 0
Rated operation current Ie at AC-15, 230 V: 6
Lovato Electric Spa
Details
CONTATTO AUX 1NC A VITE AUTOMONITORATO - LPXC01SM (8013975209196)
bloc de contact auxiliaire
Number of contacts as change-over contact: 0
Number of contacts as normally open contact: 0
Number of contacts as normally closed contact: 1
Number of fault-signal switches: 0
Rated operation current Ie at AC-15, 230 V: 6
Lovato Electric Spa