Companies found: 7
Abb Spa (11719) |
Siemens Spa (6470) |
Eaton Industries (Italy) S.r.l. (1957) |
Schneider Electric Spa (1336) |
Bticino Spa (1037) |
Hager Bocchiotti SPA (431) |
Gewiss Spa (264) |
Power circuit-breaker for trafo/generator/installation protection
Code | ||
---|---|---|
![]() | MEGATIKER M3 125 TM 4P 40A 70kA - T7304H40 (8005543686010) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 40 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 70 Overload release current setting: 32÷40 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 50A 70kA - T7304H50 (8005543686027) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 50 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 70 Overload release current setting: 40÷50 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 63A 70kA - T7304H63 (8005543686034) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 63 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 70 Overload release current setting: 50.4÷63 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 80A 70kA - T7304H80 (8005543686041) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 80 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 70 Overload release current setting: 64÷80 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 100A 100kA - T7304L100 (8005543686058) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 100 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 100 Overload release current setting: 80÷100 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 125A 100kA - T7304L125 (8005543686065) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 125 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 100 Overload release current setting: 100÷125 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 16A 100kA - T7304L16 (8005543686072) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 16 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 100 Overload release current setting: 12.8÷16 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 20A 100kA - T7304L20 (8005543686089) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 20 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 100 Overload release current setting: 16÷20 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 25A 100kA - T7304L25 (8005543686096) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 25 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 100 Overload release current setting: 20÷25 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 32A 100kA - T7304L32 (8005543686102) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 32 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 100 Overload release current setting: 25.6÷32 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 40A 100kA - T7304L40 (8005543686119) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 40 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 100 Overload release current setting: 32÷40 Adjustment range short-term delayed short-circuit release: - | ![]() |
![]() | MEGATIKER M3 125 TM 4P 50A 100kA - T7304L50 (8005543686126) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 50 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 100 Overload release current setting: 40÷50 Adjustment range short-term delayed short-circuit release: - | ![]() |