Companies found: 7
Abb Spa (11719) |
Siemens Spa (6470) |
Eaton Industries (Italy) S.r.l. (1957) |
Schneider Electric Spa (1336) |
Bticino Spa (1037) |
Hager Bocchiotti SPA (431) |
Gewiss Spa (264) |
Power circuit-breaker for trafo/generator/installation protection
Code | ||
---|---|---|
NZMN1-A63-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112759 (4015081122998) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 63 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 50÷63 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMN1-A80-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112760 (4015081123001) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 80 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 63÷80 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMN1-A100-SVE INT.AUT.RIMOV. 3P PROT.IMP. - 112761 (4015081123018) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 100 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 80÷100 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMN1-A125-SVE INT.AUT.RIMOV. 3P PROT.IMP. - 112762 (4015081123025) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 125 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 100÷125 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMN1-A20-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112776 (4015081123162) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 20 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 15÷20 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMN1-A25-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112777 (4015081123179) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 25 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 20÷25 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMN1-A32-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112778 (4015081123186) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 32 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 25÷32 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH1-A20-SVE INT.AUT.RIMOV. 3P PROT.IMP. - 112795 (4015081123353) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 20 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 15÷20 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH1-A25-SVE INT.AUT.RIMOV. 3P PROT.IMP. - 112796 (4015081123360) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 25 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 20÷25 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH1-A32-SVE INT.AUT.RIMOV. 3P PROT.IMP. - 112797 (4015081123377) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 32 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 25÷32 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH1-A40-SVE INT.AUT.RIMOV. 3P PROT.IMP. - 112798 (4015081123384) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 40 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 32÷40 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH1-A50-SVE INT.AUT.RIMOV. 3P PROT.IMP. - 112799 (4015081123391) disjoncteur pour protection de transformateur, de générateur et d'installation Rated permanent current Iu: 50 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 40÷50 A Adjustment range short-term delayed short-circuit release: 0÷0 A |