Companies found: 7
Abb Spa (11719) |
Siemens Spa (6470) |
Eaton Industries (Italy) S.r.l. (1957) |
Schneider Electric Spa (1336) |
Bticino Spa (1037) |
Hager Bocchiotti SPA (431) |
Gewiss Spa (264) |
Power circuit-breaker for trafo/generator/installation protection
Code | ||
---|---|---|
NZMH3-4-AE400-T INT.AUT.4P GUASTO. T. - 110906 (4015081104352) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 400 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA Overload release current setting: 200÷400 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH3-4-AE400/250-T INT.AUT.4P GUASTO. T. - 110907 (4015081104369) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 400 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA Overload release current setting: 200÷400 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH3-4-AE630-T INT.AUT.4P GUASTO. T. - 110908 (4015081104376) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 630 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA Overload release current setting: 315÷630 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMH3-4-AE630/400-T INT.AUT.4P GUASTO. T. - 110909 (4015081104383) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 630 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 150 kA Overload release current setting: 315÷630 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB1-A40-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112703 (4015081122530) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 40 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 32÷40 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB1-A50-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112704 (4015081122547) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 50 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 40÷50 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB1-A63-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112705 (4015081122554) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 63 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 50÷63 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB1-A80-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112706 (4015081122561) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 80 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 63÷80 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB1-A100-SVE INT.AUT.RIMOV. 3P PROT.IMP. - 112707 (4015081122578) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 100 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 80÷100 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB1-A125-SVE INT.AUT.RIMOV. 3P PROT.IMP. - 112708 (4015081122585) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 125 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 100÷125 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB1-A20-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112733 (4015081122738) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 20 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 15÷20 A Adjustment range short-term delayed short-circuit release: 0÷0 A | ||
NZMB1-A25-SVE INT.AUT.RIM. 3P PROT.IMPIANTI - 112734 (4015081122745) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 25 A Rated voltage: 440÷440 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA Overload release current setting: 20÷25 A Adjustment range short-term delayed short-circuit release: 0÷0 A |