Companies found: 7
Siemens Spa (12940) |
Abb Spa (11719) |
Eaton Industries (Italy) S.r.l. (1957) |
Schneider Electric Spa (1336) |
Bticino Spa (1037) |
Hager Bocchiotti SPA (431) |
Gewiss Spa (264) |
Power circuit-breaker for trafo/generator/installation protection
Code | ||
---|---|---|
M2 250H - ele + mis Ig tg 3P+N/2 250A 70kA - T724H250MT (8005543432211) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 250 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 70 Overload release current setting: 150÷250 Adjustment range short-term delayed short-circuit release: 150÷2500 | ||
M2 250H - ele + mis Ig tg 3P+N/2 40A 70kA - T724H40MT (8005543432242) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 40 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 70 Overload release current setting: 24÷40 Adjustment range short-term delayed short-circuit release: 24÷400 | ||
M1 160B - magnetot 3P+N/2 100A 25kA - T714B100 (8012199974378) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 100 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 Overload release current setting: 80÷100 Adjustment range short-term delayed short-circuit release: 1000÷1000 | ||
M1 160B - magnetot-diFF 3P+N/2 100A 25kA - T714B100D (8012199979045) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 100 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 Overload release current setting: 80÷100 Adjustment range short-term delayed short-circuit release: 1000÷1000 | ||
M1 160B - magnetot 3P+N/2 80A 25kA - T714B80 (8012199974309) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 80 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 Overload release current setting: 64÷80 Adjustment range short-term delayed short-circuit release: 800÷800 | ||
M1 160B - magnetot+diFF 3P+N/2 80A 25kA - T714B80D (8012199979113) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 80 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 Overload release current setting: 64÷80 Adjustment range short-term delayed short-circuit release: 800÷800 | ||
M1 160E - magnetot 3P+N/2 100A 16kA - T714E100 (8012199974293) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 100 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 16 Overload release current setting: 80÷100 Adjustment range short-term delayed short-circuit release: 1000÷1000 | ||
M1 160E - magnetot 3P+N/2 80A 16kA - T714E80 (8012199974590) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 80 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 16 Overload release current setting: 64÷80 Adjustment range short-term delayed short-circuit release: 800÷800 | ||
M1 160N - magnetot 3P+N/2 100A 50kA - T714N100 (8012199974583) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 100 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 Overload release current setting: 80÷100 Adjustment range short-term delayed short-circuit release: 1000÷1000 | ||
M1 160N - magnetot+diff 3P+N/2 100A 50kA - T714N100D (8012199979205) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 100 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 Overload release current setting: 80÷100 Adjustment range short-term delayed short-circuit release: 1000÷1000 | ||
M1 160N - magnetot 3P+N/2 80A 50kA - T714N80 (8012199974514) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 80 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 Overload release current setting: 64÷80 Adjustment range short-term delayed short-circuit release: 800÷800 | ||
M1 160N - magnetot+diff 3P+N/2 80A 50kA - T714N80D (8012199979274) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 80 Rated voltage: 220÷690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 Overload release current setting: 64÷80 Adjustment range short-term delayed short-circuit release: 800÷800 |