You must enable Javascript on your browser for the site to work optimally and display sections completely.

Companies found: 4
Siemens Spa (390)
Bticino Spa (128)
Schneider Electric Spa (125)
Dkc Europe S.r.l. (110)

Tap off unit for busbar trunk

Results 169-180 of 753
Code
Details
CASS. DERIV COMPACT NS 100/160A - KSB160DC4 (3606480005688)
tap off unit for busbar trunk
Number of conductors (without earthing): 4
Number of poles: 4
Rated current AC 50 Hz: 160 A
Rated voltage AC 50 Hz: 230÷690 V
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DER COMPACT NS 100/160A PEN - KSB160DC5 (3606480005695)
tap off unit for busbar trunk
Number of conductors (without earthing): 4
Number of poles: 3
Rated current at AC 50 Hz: 160
Rated voltage at AC 50 Hz: 230÷690
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DERIVAZ 160A NSX manovra motoriz - KSB160DD411 (3606485078762)
tap off unit for busbar trunk
Number of conductors (without earthing): 3
Number of poles: 3
Rated current AC 50 Hz: 160 A
Rated voltage AC 50 Hz: 230÷690 V
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DI DERIV 160A PER FUS NF 00 - KSB160SE4 (3606480005701)
tap off unit for busbar trunk
Number of conductors (without earthing): 4
Number of poles: 5
Rated current AC 50 Hz: 160 A
Rated voltage AC 50 Hz: 230÷690 V
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DER 160A PER FUS NF 00 PEN - KSB160SE5 (3606480005718)
tap off unit for busbar trunk
Number of conductors (without earthing): 3
Number of poles: 4
Rated current at AC 50 Hz: 160
Rated voltage at AC 50 Hz: 230÷690
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DI DER 160A PER FUS Tg 0 - KSB160SF4 (3606480005725)
tap off unit for busbar trunk
Number of conductors (without earthing): 4
Number of poles: 3
Rated current at AC 50 Hz: 160
Rated voltage at AC 50 Hz: 230÷690
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DER 160A PER FUS Tg 0 PEN - KSB160SF5 (3606480005732)
tap off unit for busbar trunk
Number of conductors (without earthing): 3
Number of poles: 3
Rated current at AC 50 Hz: 160
Rated voltage at AC 50 Hz: 230÷690
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DERIVAZ 160A per MODULARI - KSB160SM424 (3606485208619)
tap off unit for busbar trunk
Number of conductors (without earthing): 4
Number of poles: 3
Rated current AC 50 Hz: 160 A
Rated voltage AC 50 Hz: 230÷690 V
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DERIVAZ 160A per MODULARI - KSB160SM524 (3606485208626)
tap off unit for busbar trunk
Number of conductors (without earthing): 4
Number of poles: 3
Rated current at AC 50 Hz: 160
Rated voltage at AC 50 Hz: 230÷690
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DERIV COMPACT NS 250A - KSB250DC4 (3606480005756)
tap off unit for busbar trunk
Number of conductors (without earthing): 4
Number of poles: 3
Rated current at AC 50 Hz: 250
Rated voltage at AC 50 Hz: 230÷690
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DERIV COMPACT NS 250A PEN - KSB250DC5 (3606480005763)
tap off unit for busbar trunk
Number of conductors (without earthing): 4
Number of poles: 3
Rated current at AC 50 Hz: 250
Rated voltage at AC 50 Hz: 230÷690
Phase selection: FALSE
Schneider Electric Spa
Details
CASS DI DER 250A PER FUS Tg 1 - KSB250SE4 (3606480005770)
tap off unit for busbar trunk
Number of conductors (without earthing): 4
Number of poles: 5
Rated current AC 50 Hz: 250 A
Rated voltage AC 50 Hz: 230÷690 V
Phase selection: FALSE
Schneider Electric Spa