Companies found: 11
Siemens Spa (1190) |
Eaton Industries (Italy) S.r.l. (595) |
Schneider Electric Spa (343) |
Abb Spa (103) |
Lovato Electric Spa (74) |
Omron Electronics S.p.a. (47) |
Italweber Spa (24) |
Bticino Spa (22) |
Gewiss Spa (13) |
Hager Bocchiotti SPA (13) |
Vortice Spa (5) |
Motor protection circuit-breaker
Code | ||
---|---|---|
NZMB2-S250-CNA SOLO MAGN 25KA UL/CSA 250A - 102478 (4015081023660) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 8÷10 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMN2-S250-CNA SOLO MAGN 35KA UL/CSA 250A - 102479 (4015081023677) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 8÷10 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMH2-S250-CNA SOLO MAGN UL/CSA 250A - 102490 (4015081023684) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 2000÷3250 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMB1-S2-CNA SOLO MAGN 25KA UL/CSA 2A - 102907 (4015081027569) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 12÷22 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMB1-S3-CNA SOLO MAGN 25KA UL/CSA 3A - 102908 (4015081027576) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 18÷33 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMB1-S5-CNA SOLO MAGN 25KA UL/CSA 5A - 102909 (4015081027583) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 30÷55 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMB1-S8-CNA SOLO MAGN 25KA UL/CSA 8A - 103020 (4015081027590) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 48÷88 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMB1-S12-CNA SOLO MAGN 25KA UL/CSA 12A - 103021 (4015081028603) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 84÷144 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMB1-S18-CNA SOLO MAGN 25KA UL/CSA 18A - 103022 (4015081028610) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 126÷216 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMB1-S26-CNA SOLO MAGN 25KA UL/CSA 26A - 103023 (4015081028627) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 208÷338 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMB1-S33-CNA SOLO MAGN 25KA UL/CSA 33A - 103024 (4015081028634) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 264÷462 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic | ||
NZMN1-S2-CNA SOLO MAGN 35KA UL/CSA 2A - 103026 (4015081028658) motor protection circuit-breaker Overload release current setting: 0÷0 A Adjustment range undelayed short-circuit release: 12÷22 A With thermal overload protection: FALSE Phase failure sensitive: FALSE Switch off technique: Magnetic |