Classes found: 74
camera for monitoring system (342) |
door station door communication (332) |
mounting frame for door station (243) |
functional module for door communication (208) |
letterbox (204) |
Accessories/spare parts for fire detector (199) |
accessories for door communication (148) |
Movement detector for danger detection system (123) |
Matrix memory for video surveillance system (121) |
indoor station door communication (67) |
Fire detector (62) |
Accessories/spare parts for camera (surveillance system) (57) |
Accessories/spare parts for junction boxes/cases for mounting in the wall (54) |
door station set (51) |
Audio/video transmitting system (48) |
accessories for alarm systems (43) |
Video surveillance system (38) |
admittance control system (36) |
signalling and operation panel for bus system (35) |
mounting accessories for door communication (31) |
Gas detector (31) |
control element/cover plate for domestic switching devices (28) |
Central alarm panel for intrusion detection system (28) |
Recessed mounted box for doorbell (25) |
Motor siren (23) |
access control unit for bus system (23) |
power supply door communication (22) |
Opening detector for danger detection system (22) |
basic module for bus system (21) |
Electronic data medium for switchgear for danger detection system (21) |
Network switch (20) |
Control panel for escape route (20) |
Central fire alarm control panel (20) |
Optical/acoustic signal device (19) |
software for bus system (19) |
dc-power supply (19) |
Loudspeaker box (18) |
monitor for monitoring system (18) |
digital memory medium (15) |
communication column (10) |
data and communication cable (copper) (10) |
power supply for bus system (9) |
coax connector (9) |
Thermal camera (9) |
coaxial cable (8) |
distribution terminal block (7) |
Base for fire detector (7) |
accessories for movement sensor (7) |
Alarm transfer device (7) |
rechargeable battery (6) |
interface for bus system (6) |
physical sensor for bus system (6) |
Strobe luminaire (6) |
non-automatic detector for danger detection system (6) |
Holding magnet for door locking system (6) |
Accessories/spare parts for sound systems (6) |
Keyboard (4) |
Glass break/vibration detector (4) |
Protective housing for surveillance camera (4) |
signal converter for monitoring system (4) |
warning/signing plate (4) |
touch sensor for bus system (3) |
Video switch for surveillance system (3) |
external camera door communication (2) |
modular connector (2) |
Technical detector for danger detection system (2) |
Video switch (2) |
electrical door opener (1) |
Measuring instrument for temperature and climate (1) |
logic component for bus system (1) |
analogue input for bus system (1) |
light control unit for bus system (1) |
Accessories/spare parts for bus system (1) |
expansion module for surveillance systems (1) |
Code | ||
---|---|---|
MINIBARRIERE RADIO IR, ALTEZZA 2,5M - BEAMRF25SB (8023903310368) Movement detector for danger detection system Type of messaging: Passive infrared Mounting method: Surface mounting Detection range: 0 Operating current: 2.7 Operating voltage: 6÷6 | ||
SENSORE DOPPIA TECNOLOGIA DA INTERNO 12M,.. - DT011B (8023903294361) Movement detector for danger detection system Type of messaging: Infrared/microwave (Dual) Mounting method: Surface mounting Detection range: 110 Operating current: 25 Operating voltage: 9÷16 | ||
SENSORE DOPPIA TECNOLOGIA, 15M, 90? - DT015A (8023903359701) Movement detector for danger detection system Type of messaging: Infrared/microwave (Dual) Mounting method: Surface mounting Detection range: 90 Operating current: 46 Operating voltage: 9÷18 | ||
SENSORE DOPPIA TECNOLOGIA A TENDA, BIANCO - DT01CW (8023903305838) Movement detector for danger detection system Type of messaging: Infrared/microwave (Dual) Mounting method: Surface mounting Detection range: 165 Operating current: 26 Operating voltage: 9÷15 | ||
SENSORE TRIPLO IR DA ESTERNO, 180?, ANTIM. - IR180EAM (8023903323993) Movement detector for danger detection system Type of messaging: Passive infrared Mounting method: Surface mounting Detection range: 180 Operating current: 14 Operating voltage: 12÷12 | ||
SENSORE VOLUMETRICO RADIO 12M - RF12PIR (8023903357820) Movement detector for danger detection system Type of messaging: Passive infrared Mounting method: Other Detection range: 90 Operating current: 0.004 Operating voltage: 3÷3 | ||
SENSORE DOPPIO PIR EFFETTO TENDA, RF SERI.. - RF2PIRAMB (8023903299434) Movement detector for danger detection system Type of messaging: Passive infrared Mounting method: Surface mounting Detection range: 35 Operating current: 38 Operating voltage: 3÷3.6 | ||
SENSORE RADIO DOPPIO PIR DA ESTERNO - RFDP12E (8023903397055) Movement detector for danger detection system Type of messaging: Passive infrared Mounting method: Surface mounting Detection range: 100 Operating current: 31 Operating voltage: 6÷6 | ||
SENSORE RADIO DOPPIO PIR TENDA MARRONE - RFDP4CB (8023903397031) Movement detector for danger detection system Type of messaging: Passive infrared Mounting method: Surface mounting Detection range: 35 Operating current: 38 Operating voltage: 5÷5 | ||
SENSORE RADIO DOPPIO PIR TENDA BIANCO - RFDP4CW (8023903397024) Movement detector for danger detection system Type of messaging: Passive infrared Mounting method: Surface mounting Detection range: 35 Operating current: 20 Operating voltage: 5÷5 | ||
SENSORE RF DOPPIA TEC. TENDA PER SECUR HUB - RFDT12CE (8023903397079) Movement detector for danger detection system Type of messaging: Infrared/microwave (Dual) Mounting method: Surface mounting Detection range: 7.5 Operating current: 40 Operating voltage: 3.6÷3.6 | ||
SENSORE RADIO DOPPIA TECNOLOGIA ESTERNO - RFDT12E (8023903397062) Movement detector for danger detection system Type of messaging: Infrared/microwave (Dual) Mounting method: Surface mounting Detection range: 110 Operating current: 31 Operating voltage: 6÷6 |