Classes found: 50
shrink tubing (535) |
straight-through joint (294) |
Cable termination for medium and high voltage cables (183) |
adhesive tape (95) |
cable resin (55) |
Plug termination for medium and high voltage cables (43) |
branch-splice joint (set) (38) |
cable tie (30) |
repair seal (30) |
Crimp cable lug for copper conductors (30) |
end terminal (26) |
crimp splices for copper conductor (24) |
spreader cap (19) |
Reducing sleeve for copper DIN cable lugs and connectors (17) |
Accessories/spare parts for industrial connectors (17) |
Connector to screw (14) |
earthing set (14) |
Technical spray (13) |
shrink end cap (12) |
accessories for earthing and lightning (11) |
crimp cable lug for aluminium conductors (10) |
Screw cable lug (8) |
Pressure spring (8) |
wall duct for cable (5) |
Accessories/spare parts for installation and connection material (5) |
Cleaning product (5) |
Branch terminal (4) |
Lubricant (4) |
Accessories/spare parts for jointing compound (4) |
(4) |
mounting base and -element for cable ties (3) |
crimp splices for aluminium conductor (3) |
replacement blade (3) |
Cleaning cloth (3) |
box/housing for surface mounting on the wall/ceiling (3) |
(3) |
Cable stripping tool (2) |
low current connector (2) |
jointing compound (2) |
Roofing torch (2) |
Assortment box for installation- and connection material (1) |
Assortment box with heat-shrink tubing segments (1) |
Cable branch screw clamp ring (1) |
Warning tape (1) |
caulking gun (1) |
Cable sheath repair kit (1) |
measurement device for surge protection (1) |
(1) |
(1) |
Propane bottle (1) |
Code | ||
---|---|---|
Giunto derivato Y res.colata4x50/35 Y3.5/EG - 131118 (4010311053899) branch-splice joint (set) Rated voltage U0/U (Um): 0.6/1 (1.2) kV Type: Y-branch Model: Cast resin Number of conductors: 5 Nominal cross section conductor branch cable: 50÷50 mm² | ||
Giunto derivato Y res.colata4x150/70 Y4.5EG - 131119 (4010311053912) branch-splice joint (set) Rated voltage U0/U (Um): 0.6/1 (1.2) kV Type: Y-branch Model: Cast resin Number of conductors: 5 Nominal cross section conductor branch cable: 70÷70 mm² | ||
Giunto derivato Y res.colata 4x50/35 Y3EG/U - 131123 (4010311053882) branch-splice joint (set) Rated voltage U0/U (Um): 0.6/1 (1.2) kV Type: Y-branch Model: Cast resin Number of conductors: 5 Nominal cross section conductor branch cable: 35÷35 | ||
Giunto derivato Y res.colata 4x300/185 Y6EG - 131126 (4010311117089) branch-splice joint (set) Rated voltage U0/U (Um): 0.6/1 (1.2) kV Type: Y-branch Model: Cast resin Number of conductors: 5 Nominal cross section conductor branch cable: 185÷185 mm² | ||
Giunto derivato T res.colata 5x4 T1EG/UE - 131149 (4010311045191) branch-splice joint (set) Rated voltage U0/U (Um): 0.6/1 (1.2) kV Type: T-branch Model: Cast resin Number of conductors: 5 Nominal cross section conductor branch cable: 4÷4 mm² | ||
Giunto derivato T res.colata 5x25/16 T3EG/U - 131151 (4010311117072) branch-splice joint (set) Rated voltage U0/U (Um): 0.6/1 (1.2) kV Type: T-branch Model: Cast resin Number of conductors: 5 Nominal cross section conductor branch cable: 16÷16 mm² | ||
Resina a colata Pur. F.R.UG 1850ml/Uni/Al/K - 131331 (4010311086316) cable resin Material: 2-component polyurethane resin Volume: 2498 g Mining sector approval: FALSE | ||
Giunto derivato T res.colata 4x95/50 T4EG/U - 131778 (4010311053936) branch-splice joint (set) Rated voltage U0/U (Um): 0.6/1 (1.2) kV Type: T-branch Model: Cast resin Number of conductors: 4 Nominal cross section conductor branch cable: 35÷35 mm² | ||
Giunto derivato T res.colata 4x185/150 T5EG - 131854 (4010311053943) branch-splice joint (set) Rated voltage U0/U (Um): 0.6/1 (1.2) kV Type: T-branch Model: Cast resin Number of conductors: 4 Nominal cross section conductor branch cable: 70÷70 mm² | ||
Giunto derivato T res.colata 5x16/10 T2.5EG - 131855 (4010311117065) branch-splice joint (set) Rated voltage U0/U (Um): 0.6/1 (1.2) kV Type: T-branch Model: Cast resin Number of conductors: 5 Nominal cross section conductor branch cable: 10÷10 mm² | ||
Giunto diritto res.colata 4x35con.vite M13V - 131864 (4010311020389) straight-through joint Rated voltage U0/U (Um): 0.6/1 (1.2) kV Model: Cast resin Insulating material: Plastic For connection of paper- with plastic insulated cables: FALSE Number of conductors: 4 | ||
Giunto diritto res.colata 4x70con.vite M14V - 131865 (4010311020396) straight-through joint Rated voltage U0/U (Um): 0.6/1 (1.2) kV Model: Cast resin Insulating material: Plastic For connection of paper- with plastic insulated cables: FALSE Number of conductors: 4 |