Companies found: 40
Frer Srl (1460) |
Cembre Spa (711) |
Bticino Spa (133) |
Weidmuller Srl (111) |
Abb Spa (103) |
RIMSA P. LONGONI SRL (90) |
SCHMERSAL ITALIA S.R.L. (65) |
Schneider Electric Spa (57) |
REICHLE + DE MASSARI ITALIA S.R.L. (41) |
Elettronica Kros S.r.l. (30) |
ZG LIGHTING SRL SOCIO UNICO (23) |
FIORE S.R.L. (16) |
Hellermanntyton S.r.l. (15) |
Asita Srl (13) |
Trilux Italia Srl (12) |
UNIFIX SWG SRL (10) |
Vimar Spa (10) |
A.t.e.c. Srl (9) |
F.A.I. SRL (6) |
Fbt Elettronica Spa (6) |
PEPPERL+FUCHS FA ITALIA SRL (5) |
Elcart Distribution Spa (4) |
K2M SRL (4) |
Techtronic Industries Italia Srl Unico Socio (4) |
FLUKE ITALIA S.r.l. (3) |
Melchioni S.p.A. (3) |
Phoenix Contact Spa (3) |
Alpha Elettronica Srl (2) |
Ave Spa (2) |
URMET SPA (2) |
Beta Utensili S.p.A. (1) |
Bm Spa (1) |
Etelec Italia Spa (1) |
Fracarro Radioindustrie Srl (1) |
Ht Italia Srl (1) |
LEF LIGHTING SRL (1) |
MURRELEKTRONIK SRL (1) |
Orbis Italia Spa (1) |
Sick Spa (1) |
Siemens Spa (1) |
Classes found: 29
cable coding system (708) |
current transformer (154) |
Multifunction measuring instrument (86) |
capacitor contactor (63) |
Residual current monitoring relay with transformer (59) |
light technical accessories for luminaires (39) |
frequency converter =< 1 kv (36) |
Table luminaire (27) |
current monitoring relay (24) |
Machine and work bench luminaire (23) |
voltage monitoring relay (16) |
repair seal (15) |
Clamp measuring instrument (14) |
power circuit-breaker for trafo/generator/installation protection (12) |
hifi amplifier (8) |
Multi-functional measuring- and monitoring instrument (6) |
Current value transformer (4) |
Multimeter (3) |
mounting for labelling material (3) |
Loudspeaker box (2) |
multi operating device for bus system (2) |
Control panel for escape route (2) |
Module for head end station (1) |
tripping bloc for power circuit-breaker (1) |
electronic switch (1) |
Fieldbus, decentr. periphery - analogue I/O module (1) |
effective power converter meter for installation (1) |
accessories for low-voltage switch technology (1) |
Electrical accessories/spare parts for luminaires (1) |
Code | ||
---|---|---|
NS630bN fisso ant 3P Mlogic 2.0 - 33460 (3303430334606) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 630 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 252÷630 A Adjustment range short-term delayed short-circuit release: - A | ||
NS630bN fisso ant 4P Mlogic 2.0 - 33463 (3303430334637) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 630 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 252÷630 A Adjustment range short-term delayed short-circuit release: - A | ||
NS800N fisso ant 3P Mlogic 2.0 - 33466 (3303430334668) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 800 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 320÷800 A Adjustment range short-term delayed short-circuit release: - A | ||
NS800N fisso ant 4P Mlogic 2.0 - 33469 (3303430334699) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 800 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 320÷800 A Adjustment range short-term delayed short-circuit release: - A | ||
NS1000N fisso ant 3P Mlogic 2.0 - 33472 (3303430334729) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 1000 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 400÷1000 A Adjustment range short-term delayed short-circuit release: - A | ||
NS1000N fisso ant 4P Mlogic 2.0 - 33475 (3303430334750) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 1000 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 400÷1000 A Adjustment range short-term delayed short-circuit release: - A | ||
NS1250N fisso ant 3P Mlogic 2.0 - 33478 (3303430334781) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 1250 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 500÷1250 A Adjustment range short-term delayed short-circuit release: - A | ||
NS1250N fisso ant 4P Mlogic 2.0 - 33480 (3303430334804) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 1250 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 500÷1250 A Adjustment range short-term delayed short-circuit release: - A | ||
NS1600N fisso ant 3P Mlogic 2.0 - 33482 (3303430334828) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 1600 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 640÷1600 A Adjustment range short-term delayed short-circuit release: - A | ||
NS1600N fisso ant 4P Mlogic 2.0 - 33484 (3303430334842) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 1600 A Rated voltage: 690÷690 V Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 50 kA Overload release current setting: 640÷1600 A Adjustment range short-term delayed short-circuit release: - A | ||
KCMA-32-600-1A-5VA-1 - 1481980000 (4050118290936) current transformer Model: Cable rebuilding current converter Primary rated current: 600 Secondary rated current: 1 Secondary rated apparent power: 5 Accuracy class: 1 | ||
KCMA-32-400-1A-5VA-1 - 1481990000 (4050118291063) current transformer Model: Cable rebuilding current converter Primary rated current: 400 Secondary rated current: 1 Secondary rated apparent power: 5 Accuracy class: 1 |