power circuit-breaker for trafo/generator/installation protection (14) |
Code | ||
---|---|---|
E2.2S/E9 1250 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104455R1 (8015644065355) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 1250 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 500.0÷1250 Adjustment range short-term delayed short-circuit release: 750.0÷12500 | ||
E2.2S/E9 2000 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104460R1 (8015644065409) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 2000 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 800.0÷2000 Adjustment range short-term delayed short-circuit release: 1200.0÷20000 | ||
E2.2H/E9 1250 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104485R1 (8056221026406) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 1250 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 500.0÷1250 Adjustment range short-term delayed short-circuit release: 750.0÷12500 | ||
E2.2H/E9 2500 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104495R1 (8015644065751) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 2500 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 1000.0÷2500 Adjustment range short-term delayed short-circuit release: 1500.0÷25000 | ||
E4.2S/E9 3200 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104510R1 (8015644065904) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 3200 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 1280.0÷3200 Adjustment range short-term delayed short-circuit release: 1920.0÷32000 | ||
E4.2H/E9 3200 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104530R1 (8015644066109) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 3200 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 1280.0÷3200 Adjustment range short-term delayed short-circuit release: 1920.0÷32000 | ||
E4.2H/E9 4000 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104535R1 (8056221026543) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 4000 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 1600.0÷4000 Adjustment range short-term delayed short-circuit release: 2400.0÷40000 | ||
E6.2X/E9 5000 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104550R1 (8015644066307) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 5000 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 2000.0÷5000 Adjustment range short-term delayed short-circuit release: 3000.0÷50000 | ||
E6.2H/E9 5000 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104638R1 (8015644067182) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 5000 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 2000.0÷5000 Adjustment range short-term delayed short-circuit release: 3000.0÷50000 | ||
E6.2H/E9 6300 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104643R1 (8056221026666) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 6300 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 2520.0÷6300 Adjustment range short-term delayed short-circuit release: 3780.0÷63000 | ||
E2.2S/E9 2500 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104465R1 (8015644065454) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 2500 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 1000.0÷2500 Adjustment range short-term delayed short-circuit release: 1500.0÷25000 | ||
E2.2H/E9 2000 EkipHi-Tch LSIG 4pWMP 900V - 1SDA104490R1 (8015644065706) power circuit-breaker for trafo/generator/installation protection Rated permanent current Iu: 2000 Rated voltage: 900÷900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: - Overload release current setting: 800.0÷2000 Adjustment range short-term delayed short-circuit release: 1200.0÷20000 |